Selection of operation mode and operation location
Selects the command source of the PU operation mode (Pr. 551)
Any of the operation panel, PU connector, Ethernet connector (only FR-E700 SC ENE), or USB connec-
tor can be specified as the command source in the PU operation mode.
In the PU operation mode, set Pr. 551 to "2" when executing parameter write, start command or fre-
quency command during the RS-485 communication with PU communication.
NOTES
When performing the RS-485 communication with the PU connector when Pr. 551 = 9999, PU
mode command source does not automatically change to the PU connector. Change to the net-
work operation mode to change the command source.
When "2" (NET mode PU connector) is set in Pr. 550 and "2" (PU mode PU connector) is set in Pr.
551, PU operation mode has priority. When the communication option is not fitted for the FR-E700
SC EC, therefore, the operation mode cannot be switched to the network operation mode.
Changed setting value is made valid when powering on or resetting the inverter.
The Modbus®-RTU protocol cannot be used in the PU operation mode. Select network operation
mode (NET mode command source).
All of the operation mode indicator (
thecommand source for the FR-E700 SC EC is not the operation panel.
Pr. 550 Pr. 551
0
(initial
value
for FR-
E700 SC
ENE)
2
9999
(initial
value
for FR-
E700 SC
EC))
Tab. 6-61: Parameter 550 and 551 settings
The Modbus®-RTU protocol cannot be used in the PU operation mode. When using the Mod-
bus®-RTU protocol, set Pr. 550 to "2".
For FR-E700 SC EC: When the communication option is not fitted, the operation mode cannot be
switched to the network operation mode.
When Pr. 551 = "9999", the priorities of the PU control source is USB connector > parameter unit
(FR-PU04/FR-PU07) > operation panel.
6 - 222
Operation
USB
Panel
Connector
2
3
PU
4
PU
9999
(initial
PU
PU
value)
2
3
PU
4
PU
9999
(initial
PU
PU
value)
2
3
PU
4
PU
9999
(initial
PU
PU
value)
) of the operation panel turns OFF when
Command Source
PU connector
Parameter
RS-485
Unit
Communication
PU
PU
PU
PU
PU
NET
NET
NET
PU
PU
PU
NET
NET
PU
NET
Parameter
Communica-
tion Option
(FR-E700 SC
Remarks
EC)/
Ethernet
connector (FR-
E700 SC ENE)
NET
NET
NET
NET
Switching to NET opera-
tion mode disabled
NET
Communication option
NET
fitted
Communication option
not fitted
Communication option
NET
fitted
Communication option
not fitted
Communication option
NET
fitted
Communication option
not fitted

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720s sc ecFr-e720s sc eneFr-e740 sc ecFr-e740 sc ene

Table of Contents