Initial settings and specifications of Ethernet communication (FR-E700 SC ENE)
Use the following parameters to perform required settings for Ethernet communication between the
inverter and other devices.
To make communication between other devices and the inverter, perform the initial settings of the in-
verter parameters to match the communication specifications of the devices. Data communication
cannot be made if the initial settings are not made or if there is any setting error.
Pr. No.
Name
442
Default gateway address 1
443
Default gateway address 2
444
Default gateway address 3
445
Default gateway address 4
805
Ethernet IP address 1
806
Ethernet IP address 2
807
Ethernet IP address 3
808
Ethernet IP address 4
809
Subnet mask 1
810
Subnet mask 2
811
Subnet mask 3
812
Subnet mask 4
Ethernet communication
830
network number
Ethernet communication
831
station number
Link speed and duplex mode
832
selection
833
Ethernet function selection 1
834
Ethernet function selection 2
835
Ethernet function selection 3
837
Ethernet IP filter address 1
838
Ethernet IP filter address 2
839
Ethernet IP filter address 3
840
Ethernet IP filter address 4
Ethernet IP filter address 2
841
range specification
Ethernet IP filter address 3
842
range specification
Ethernet IP filter address 4
843
range specification
FR-E700 SC EC/ENE
Initial Value
Setting Range Description
0
0–255
Enter the IP address of the default gateway, which
0
0–255
is a device connecting the different networks, to
establish a communication between the inverter
0
0–255
and the devices outside the inverter network.
0
0–255
192
0–255
168
0–255
Enter the IP address of the inverter to be connected
to Ethernet.
50
0–255
1
0–255
255
0–255
255
0–255
Enter the subnet mask of the network to which the
inverter belongs.
255
0–255
0
0–255
1
1–239
Enter the network number.
1
1–120
Enter the station number.
Set the communication speed and the
0
0–4
communication mode (full-duplex/half-duplex).
31
0, 10, 20, 30, 31,
20
Set the application, protocol, etc.
36, 38, 9999
9999
0
0–255
0
0–255
0
0–255
Set the range of connectable IP addresses for the
0
0–255
network devices.
(When Pr. 837 to Pr. 840 = "0 (initial value)", the
function is invalid.)
9999
0–255, 9999
9999
0–255, 9999
9999
0–255, 9999
Communication operation and setting
Parameters referred to
Refer to
Section
6 - 283

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720s sc ecFr-e720s sc eneFr-e740 sc ecFr-e740 sc ene

Table of Contents