Misoperation prevention and parameter setting restriction
Write parameters during operation (Pr. 77 = 2)
Parameters can always be written. The following parameters cannot be written during operation if
Pr. 77 = 2. Stop operation when changing their parameter settings.
Parameter
178–184
190–192
Tab. 6-51: Parameters that cannot be written during operation
6 - 196
Name
23
Stall prevention operation level compensation factor at double speed
40
RUN key rotation direction selection
48
Second stall prevention operation current
60
Energy saving control selection
61
Reference current
66
Stall prevention operation reduction starting frequency
71
Applied motor
79
Operation mode selection
80
Motor capacity (simple magnetic flux vector control)
81
Number of motor poles
82
Motor excitation current
83
Motor rated voltage
84
Rated motor frequency
90–94
Motor constants
96
Auto tuning setting/status
Input terminal function selection
Output terminal function selection
277
Stall prevention operation current switchover
292
Automatic acceleration/deceleration
293
Acceleration/deceleration separate selection
298
Frequency search gain
Digital input unit selection
329
(Parameter for the plug-in option FR-A7AX-Ekit-SC-E)
450
Second applied motor
Frequency command sign selection (CC-Link)
541
(Parameter for the plug-in option FR-A7NC-Ekit-SC-E)
800
Control method selection
859
Torque current
Parameter