Wiring
Using an external power supply
● Source logic type
When using an external power supply for transistor output, use terminal SD as a common to
prevent misoperation caused by undesirable current.
● Sink logic type
Use terminal PC as a common terminal to prevent a malfunction caused by undesirable current.
(Do not connect terminal SD of the inverter with terminal 0 V of the external power supply. When
using terminals PC-SD as a 24 V DC power supply, do not install a power supply in parallel in the
outside of the inverter. Doing so may cause a malfunction due to undesirable current.)
FR-E700 SC EC/ENE
AY80
Inverter
Current
AY40
Inverter
Current
Control circuit specifications
Fig. 3-19:
Using an external power supply in connection with
the outputs of a PLC
Fig. 3-20:
Using an external power supply in connection with
the outputs of a PLC
I001031E
I001030E
3 - 29