Basic settings
5.3.3

Perform frequency setting by analog voltage input

The frequency setting potentiometer is supplied with 5 V of power from the inverter (terminal 10).
Fig. 5-26: Frequency setting by analog voltage input
FR-E700 SC EC/ENE
Power supply
Forward rotation start
Reverse rotation start
Frequency setting
potentiometer
(1 k /2 W)
Inverter
Motor
External operation
I001090E