PU operation mode
Change the acceleration time using Pr. 7 (refer to section 5.1.5) and the deceleration time using Pr. 8
(refer to section 5.1.5).
The maximum output frequency is set in Pr. 1. (Refer to section 5.1.4.)
NOTES
Press the digital dial to show the set frequency.
The digital dial can also be used like a potentiometer to perform operation. (Refer to section 5.2.2).
Use Pr. 295 "Magnitude of frequency change setting" to change the frequency setting increments
of the digital dial.
5 - 22