Cooling-Water Supply; Mechanical Data; Lubrication Data - Edwards HV8000 VF Instruction Manual

Booster pumps
Table of Contents

Advertisement

A311-03-880 Issue A
Table 2 - Performance data: safe area HV8000 pumps (continued)
Maximum pressure rise (between HV8000 pump inlet and outlet)
Maximum motor power for a directly (bell housing) mounted motor
Maximum inlet gas temperature
Maximum outlet gas temperature
Maximum gas temperature rise (between HV8000 inlet and outlet)
*
On a pump used with DoL (Direct On Line) starting, this is the critical backing pressure at which the pump
must be shut down (see
Section
1.2).
2.4

Cooling-water supply

Maximum supply pressure
Maximum supply temperature
Minimum cooling-water flow rate
2.5

Mechanical data

Dimensions
Mass
HV8000VF
HV8000HF
2.6

Lubrication data

Recommended oil
Oil capacities
HV8000VF
HV8000HF
Page 8
Section
2.2). This is not applicable to pumps operated with inverters (See
Table 3 - Cooling-water supply data
Table 4 - Mechanical data
See
Figure 2
to
5
Bareshaft
570 kg, 1257 lb
570 kg, 1257 lb
Table 5 - Lubrication data
Mobil SHC 629
Shaft-seals oil reservoir
0.2 litres, 0.05 US gal
0.2 litres, 0.05 US gal
Edwards and the Edwards logo are trademarks of Edwards Limited.
HV8000 (50 Hz)
190 mbar
3
1.9 x 10
Pa
2.75 psi
18.5 kW
25 hp
60 °C
140 °F
300 °C
572 °F
240 °C
464 °F
5
3 bar gauge, 3 x 10
Pa, 44 psi
35 °C, 95 °F
-1
15 l min
, 3.96 US gal min
With 50 Hz motor
670 kg, 1474 lb
670 kg, 1474 lb
Drive end cover
3.5 litres, 0.92 US gal
2.0 litres, 0.63 US gal
© Edwards Limited 2014. All rights reserved.
HV8000 (60 Hz)
120 mbar
3
1.2 x 10
Pa
1.74 psi
18.5 kW
25 hp
60 °C
140 °F
300 °C
572 °F
240 °C
464 °F
-1
With 60 Hz motor
664 kg, 1460 lb
664 kg, 1460 lb
Non-drive end cover
4.6 litres, 1.21 US gal
2.3 litres, 0.61 US gal

Hide quick links: