Symptom:
*CHECKING CHARGING SYSTEM OPERATION WITH NO DTCS
GENERATOR BELT CONDITION
DTC RESET
WIRE HARNESS INSPECTION
RESISTANCE IN THE BATTERY POSITIVE CIRCUIT
(K125) GENERATOR FIELD SOURCE CIRCUIT OPEN
GENERATOR FIELD COIL HIGH RESISTANCE
(K20) GEN FIELD CONTROL CIRCUIT OPEN
RESISTANCE IN THE GENERATOR GROUND
PCM
TEST
1
NOTE: Verify that the Battery is able to pass a load test before continuing.
Ignition on, engine not running.
With the DRBIII , read the Battery voltage and record the results.
Measure Battery voltage between the Battery Positive and Negative Terminals and
record the results.
Compare the two voltage readings.
Is the voltage difference less than one volt?
Yes → Go To 2
→ Go To 8
No
2
Ignition on, engine not running.
Measure the voltage between the Generator B+ Terminal and the Battery+ Post.
Caution: Ensure all wires are clear of the engine's moving parts.
Start the engine.
Is the voltage above 0.4 of a volt?
Yes → Repair the excessive resistance in the Battery Positive circuit
→ Go To 3
No
3
Ignition on, engine not running.
Record all DTCs and freeze frame data, now erase Codes.
Carefully inspect all connectors for corrosion or spread terminals before continuing.
With the DRBIII actuate the Generator Field Driver.
Measure the voltage of the (K125) Generator Field Source circuit by backprobing the
back of Generator Field harness connector.
Is the voltage above 10.0 volts?
Yes → Go To 4
→ Repair the (K125) Generator Field Source circuit for an open or
No
POSSIBLE CAUSES
ACTION
between the Generator and Battery .
Perform POWERTRAIN VERIFICATION TEST VER - 3.
short to ground.
Perform POWERTRAIN VERIFICATION TEST VER - 3.
DRIVEABILITY - GAS