Passenger Window Switch Short To Ground - Dodge ZB 2005 Service Manual

Table of Contents

Advertisement

Symptom:

PASSENGER WINDOW SWITCH SHORT TO GROUND

When Monitored and Set Condition:
PASSENGER WINDOW SWITCH SHORT TO GROUND
When Monitored: Whenever the ignition is in the RUN or ACCESSORY position.
Set Condition: When the BCM senses that the voltage on the Passenger Window Switch
Mux circuit is less than 0.69 volts for longer than 10 seconds.
DTC PRESENT
SWITCH SHORTED
PASSENGER WINDOW SWITCH MUX WIRE SHORT TO GROUND
BODY CONTROL MODULE - PASSENGER WINDOW SWITCH MUX CIRCUIT SHORTED
TEST
1
Turn the ignition on.
With the DRBIII , erase DTCs.
Cycle the ignition switch from Off to Run.
Operate the Passenger Window Motor.
With the DRBIII , read DTCs.
Does the DRBIII
GROUND?
Yes → Go To 2
→ The condition that caused the code to set is not present at this
No
2
Disconnect the Window Switch connector.
Turn the ignition on.
Measure the voltage between Passenger Switch Mux circuit and ground.
Is the voltage approximately 5.0 volts?
Yes → Replace the Window Switch.
→ Go To 3
No
POSSIBLE CAUSES
ACTION
display PASSENGER WINDOW SWITCH SHORTED TO
time. Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.
359
POWER WINDOWS
APPLICABILITY
All
All

Advertisement