Data Readouts - Danfoss VLT FC 100 Series Programming Manual

Hvac drive
Hide thumbs Also See for VLT FC 100 Series:
Table of Contents

Advertisement

Parameter Lists
Par.
Parameter description
No. #
15-63 Option Serial No
15-70 Option in Slot A
15-71 Slot A Option SW Version
15-72 Option in Slot B
15-73 Slot B Option SW Version
15-74 Option in Slot C0
15-75 Slot C0 Option SW Version
15-76 Option in Slot C1
15-77 Slot C1 Option SW Version
15-9* Parameter Info
15-92 Defined Parameters
15-93 Modified Parameters
15-98 Drive Identification
15-99 Parameter Metadata
Table 5.16

5.1.16 16-** Data Readouts

Par.
Parameter description
No. #
16-0* General Status
16-00 Control Word
16-01 Reference [Unit]
16-02 Reference %
16-03 Status Word
16-05 Main Actual Value [%]
16-09 Custom Readout
16-1* Motor Status
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor voltage
16-13 Frequency
16-14 Motor Current
16-15 Frequency [%]
16-16 Torque [Nm]
16-17 Speed [RPM]
16-18 Motor Thermal
16-22 Torque [%]
16-26 Power Filtered [kW]
16-27 Power Filtered [hp]
16-3* Drive Status
16-30 DC Link Voltage
16-32 Brake Energy /s
16-33 Brake Energy /2 min
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-36 Inv. Nom. Current
16-37 Inv. Max. Current
16-38 SL Controller State
®
VLT
HVAC Drive Programming Guide
Default value
4 set-up
(SR = Size related)
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
(SR = Size related)
0 N/A
0.000 ReferenceFeedbackUnit
0.0 %
0 N/A
0.00 %
0.00 CustomReadoutUnit
0.00 kW
0.00 hp
0.0 V
0.0 Hz
0.00 A
0.00 %
0.0 Nm
0 RPM
0 %
0 %
0.000 kW
0.000 hp
0 V
0.000 kW
0.000 kW
0 °C
0 %
ExpressionLimit
ExpressionLimit
0 N/A
MG11CD22 - VLT
®
is a registered Danfoss trademark
Change during
operation
sion index
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
4 set-up
Change during
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Conver-
Type
0
VisStr[18]
0
VisStr[30]
0
VisStr[20]
0
VisStr[30]
0
VisStr[20]
0
VisStr[30]
0
VisStr[20]
0
VisStr[30]
0
VisStr[20]
0
Uint16
0
Uint16
0
VisStr[40]
0
Uint16
Conver-
Type
sion index
0
V2
-3
Int32
-1
Int16
0
V2
-2
N2
-2
Int32
1
Int32
-2
Int32
-1
Uint16
-1
Uint16
-2
Int32
-2
N2
-1
Int32
67
Int32
0
Uint8
0
Int16
0
Int32
-3
Int32
0
Uint16
0
Uint32
0
Uint32
100
Uint8
0
Uint8
-2
Uint32
-2
Uint32
0
Uint8
5-17
5
5