Parameter Description
3
3
[54] Auto start
[55] DigiPot
Increase
[56] DigiPot
Decrease
[57] DigiPot Clear
[60] Counter A (up) (Terminal 29 or 33 only) Input for increment
[61] Counter A
(down)
[62] Reset Counter
A
[63] Counter B (up) (Terminal 29 and 33 only) Input for
[64] Counter B
(down)
[65] Reset Counter
B
[66] Sleep Mode
[68] Timed Actions
Disabled
[69] Constant OFF
[70] Constant ON
[78] Reset
Preventive
Maintenance
Word
[80] PTC Card 1
5-10 Terminal 18 Digital Input
Same options and functions as parameter group 5-1*, except for
Pulse input.
Option:
[8]
*
3-44
®
VLT
Hand Start and Auto-Start, the function will
be Auto-Start. If pressing the Off button on
the LCP, the motor will stop regardless of
signals on Hand Start and Auto-Start.
A signal applied will put the Adjustable
frequency drive into auto mode as if the
LCP button Auto On has been pressed. See
also Hand Start [53]
Uses the input as an INCREASE signal to the
Digital Potentiometer function described in
parameter group 3-9*
Uses the input as a DECREASE signal to the
Digital Potentiometer function described in
parameter group 3-9*
Uses the input to CLEAR the Digital Potenti-
ometer reference described in parameter
group 3-9*
counting in the SLC counter.
(Terminal 29 or 33 only) Input for
decrement counting in the SLC counter.
Input for reset of counter A.
increment counting in the SLC counter.
(Terminal 29 and 33 only) Input for
decrement counting in the SLC counter.
Input for reset of counter B.
Forces Adjustable frequency drive into
Sleep Mode (see parameter group 22-4*).
Reacts on the rising edge of signal applied!
Timed actions are disabled. See parameter
group 23-0* Timed Actions.
Timed Actions are set for Constant OFF. See
parameter group 23-0* Timed Actions.
Timed Actions are set for Constant ON. See
parameter group 23-0* Timed Actions.
Resets all data in 16-96 Maintenance Word
to 0.
All digital inputs can be set to PTC card 1
[80]. However, only one digital input must
be set to this choice.
Function:
Start
MG11CD22 - VLT
HVAC Drive Programming Guide
5-11 Terminal 19 Digital Input
Same options and functions as parameter group 5-1*, except for
Pulse input.
Option:
[0]
*
5-12 Terminal 27 Digital Input
Option:
[2]
Coast inverse Functions are described under parameter
*
3.7.4 5-13 Terminal 29 Digital Input
5-13 Terminal 29 Digital Input
Option:
Function:
Select the function from the available digital input
range and the additional options [60], [61], [63] and
[64]. Counters are used in smart logic control
functions.
[14]
Jog Functions are described under 5-1* Digital Inputs
*
5-14 Terminal 32 Digital Input
Option:
[0]
No Operation Same options and functions as parameter
*
5-15 Terminal 33 Digital Input
Option:
[0]
No Operation Same options and functions as parameter
*
5-16 Terminal X30/2 Digital Input
This parameter is active when option module MCB 101 is
installed in the Adjustable frequency drive. Same options and
functions as parameter group 5-1* except for Pulse input [32].
Option:
[0]
*
5-17 Terminal X30/3 Digital Input
This parameter is active when option module MCB 101 is
installed in the Adjustable frequency drive. Same options and
functions as parameter group 5-1* except for Pulse input [32].
Option:
[0]
*
5-18 Terminal X30/4 Digital Input
This parameter is active when option module MCB 101 is
installed in the Adjustable frequency drive. Same options and
functions as parameter group 5-1* except for Pulse input [32].
Option:
[0]
*
®
is a registered Danfoss trademark
Function:
No operation
Function:
group 5-1* Digital Inputs
Function:
group 5-1* Digital Inputs, except for Pulse
input.
Function:
group 5-1* Digital Inputs.
Function:
No operation
Function:
No operation
Function:
No operation