Danfoss VLT FC 100 Series Programming Manual page 237

Hvac drive
Hide thumbs Also See for VLT FC 100 Series:
Table of Contents

Advertisement

Parameter Lists
Par.
Parameter description
No. #
16-39 Control Card Temp.
16-40 Logging Buffer Full
16-41 Logging Buffer Full
16-43 Timed Actions Status
16-49 Current Fault Source
16-5* Ref. & Feedb.
16-50 External Reference
16-52 Feedback [Unit]
5
5
16-53 Digi Pot Reference
16-54 Feedback 1 [Unit]
16-55 Feedback 2 [Unit]
16-56 Feedback 3 [Unit]
16-58 PID Output [%]
16-6* Inputs & Outputs
16-60 Digital Input
16-61 Terminal 53 Switch Setting
16-62 Analog Input 53
16-63 Terminal 54 Switch Setting
16-64 Analog Input 54
16-65 Analog Output 42 [mA]
16-66 Digital Output [bin]
16-67 Pulse Input #29 [Hz]
16-68 Pulse Input #33 [Hz]
16-69 Pulse Output #27 [Hz]
16-70 Pulse Output #29 [Hz]
16-71 Relay Output [bin]
16-72 Counter A
16-73 Counter B
16-75 Analog In X30/11
16-76 Analog In X30/12
16-77 Analog Out X30/8 [mA]
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1
16-82 Fieldbus REF 1
16-84 Comm. Option Status
16-85 FC Port CTW 1
16-86 FC Port REF 1
16-9* Diagnosis Readouts
16-90 Alarm Word
16-91 Alarm word 2
16-92 Warning Word
16-93 Warning word 2
16-94 Ext. Status Word
16-95 Ext. Status Word 2
16-96 Maintenance Word
Table 5.17
5-18
®
VLT
HVAC Drive Programming Guide
Default value
(SR = Size related)
0 °C
All set-ups
[0] No
All set-ups
0 N/A
All set-ups
[0] Timed Actions Auto
All set-ups
0 N/A
All set-ups
0.0 N/A
All set-ups
0.000 ProcessCtrlUnit
All set-ups
0.00 N/A
All set-ups
0.000 ProcessCtrlUnit
All set-ups
0.000 ProcessCtrlUnit
All set-ups
0.000 ProcessCtrlUnit
All set-ups
0.0 %
All set-ups
0 N/A
All set-ups
[0] Current
All set-ups
0.000 N/A
All set-ups
[0] Current
All set-ups
0.000 N/A
All set-ups
0.000 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0.000 N/A
All set-ups
0.000 N/A
All set-ups
0.000 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
MG11CD22 - VLT
®
is a registered Danfoss trademark
4 set-up
Change during
operation
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
Conver-
Type
sion index
100
Uint8
-
Uint8
0
VisStr[50]
-
Uint8
0
Uint8
-1
Int16
-3
Int32
-2
Int16
-3
Int32
-3
Int32
-3
Int32
-1
Int16
0
Uint16
-
Uint8
-3
Int32
-
Uint8
-3
Int32
-3
Int16
0
Int16
0
Int32
0
Int32
0
Int32
0
Int32
0
Int16
0
Int32
0
Int32
-3
Int32
-3
Int32
-3
Int16
0
V2
0
N2
0
V2
0
V2
0
N2
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32