Parameter Description
9-71 Profibus Save Data Values
Option:
Function:
Parameter values changed via Profibus are not
automatically stored in non-volatile memory.
Use this parameter to activate a function that
stores parameter values in the EEPROM non-
volatile memory, so changed parameter values
will be retained at power-down.
[0]
Off
Deactivates the non-volatile storage function.
*
[1]
Store edit
Stores all parameter values for all set-ups in the
setup
non-volatile memory. The selection returns to
Off [0] when all parameter values have been
stored.
[2]
Store all
Stores all parameter values for all set-ups in the
setups
non-volatile memory. The selection returns to
Off [0] when all parameter values have been
stored.
9-72 ProfibusDriveReset
Option:
Function:
[0]
No action
*
[1]
Power-on
Resets Adjustable frequency drive upon
reset
power-up, as for power-cycle.
[3]
Comm
Resets the Profibus option only, useful after
option reset
changing certain settings in parameter
group 9-**, e.g., 9-18 Node Address.
When reset, the Adjustable frequency drive
disappears from the serial communication
bus, which may cause a communication
error from the master.
9-80 Defined Parameters (1)
Array [116]
No LCP access
Read only
Range:
Function:
0
[0 - 9999 ] This parameter displays a list of all the defined
*
Adjustable frequency drive parameters available
for Profibus.
9-81 Defined Parameters (2)
Array [116]
No LCP access
Read only
Range:
Function:
0
[0 - 9999 ] This parameter displays a list of all the defined
*
Adjustable frequency drive parameters available
for Profibus.
®
VLT
HVAC Drive Programming Guide
9-82 Defined Parameters (3)
Array [116]
No LCP access
Read only
Range:
0
9-83 Defined Parameters (4)
Array [116]
No LCP access
Read only
Range:
0
9-90 Changed Parameters (1)
Array [116]
No LCP access
Read only
Range:
0
9-91 Changed Parameters (2)
Array [116]
No LCP access
Read only
Range:
0
9-92 Changed Parameters (3)
Array [116]
No LCP access
Read only
Range:
0
MG11CD22 - VLT
®
is a registered Danfoss trademark
Function:
[0 - 9999 ] This parameter displays a list of all the defined
*
Adjustable frequency drive parameters available
for Profibus.
Function:
[0 - 9999 ] This parameter displays a list of all the defined
*
Adjustable frequency drive parameters available
for Profibus.
Function:
[0 - 9999 ] This parameter displays a list of all the
*
Adjustable frequency drive parameters
deviating from default setting.
Function:
[0 - 9999 ] This parameter displays a list of all the
*
Adjustable frequency drive parameters
deviating from default setting.
Function:
[0 - 9999 ] This parameter displays a list of all the
*
Adjustable frequency drive parameters
deviating from default setting.