Parameter Description
8-91 Bus Jog 2 Speed
Range:
200 RPM
[ 0 - par. 4-13
*
3
3
RPM]
8-94 Bus Feedback 1
Range:
0
[-200 -
*
200 ]
8-95 Bus Feedback 2
Range:
0
[-200 - 200 ]
*
8-96 Bus Feedback 3
Range:
0
[-200 - 200 ]
*
3-66
VLT
Function:
Enter the jog speed. This is a fixed
jog speed activated via the serial
port or serial communication bus
option.
Function:
Write a feedback to this parameter via the serial
communication port or serial communication
bus option. This parameter must be selected in
20-00 Feedback 1 Source, 20-03 Feedback 2
Source or 20-06 Feedback 3 Source as a feedback
source.
Function:
See 8-94 Bus Feedback 1 for further details.
Function:
See 8-94 Bus Feedback 1 for further details.