Parameter Description
26-31 Terminal X42/5 High Voltage
Range:
10.00 V
[
*
3
3
10.00 V]
26-34 Term. X42/5 Low Ref./Feedb. Value
Range:
0.000
[-999999.999 -
*
999999.999 ]
26-35 Term. X42/5 High Ref./Feedb. Value
Range:
100.000
[-999999.999 -
*
999999.999 ]
26-36 Term. X42/5 Filter Time Constant
Range:
0.001 s
[0.001 -
*
10.000 s]
26-37 Term. X42/5 Live Zero
Option:
[0]
Disabled
[1]
Enabled
*
3.24.5 26-4* Analog Out X42/7
Parameters for configuring the scaling and output function
for analog output, terminal X42/7.
3-176
Function:
par. 6-30 -
Enter the high voltage value. This
analog input scaling value should
correspond to the high reference/
feedback value set in 26-35 Term. X42/5
High Ref./Feedb. Value.
Function:
Enter the analog input scaling
value that corresponds to the low
voltage value set in 26-30 Terminal
X42/5 Low Voltage.
Function:
Enter the analog input scaling
value that corresponds to the
high voltage value set in
26-21 Terminal X42/3 High
Voltage.
Function:
Enter the time constant. This is a first-
order digital low pass filter time constant
for suppressing noise in terminal X42/5. A
high time constant value improves
dampening but also increases the time
delay through the filter. This parameter
cannot be adjusted while the motor is
running.
Function:
This parameter makes it possible to enable the
live zero monitoring, for example where the
analog input is a part of the adjustable frequency
drive control, rather than being used as part of a
decentral I/O system, such as a building
management system.
MG11CD22 - VLT
®
VLT
HVAC Drive Programming Guide
26-40 Terminal X42/7 Output
Option:
[0]
No operation
*
[100] Output freq.
0-100
[101] Reference Min-
Max
[102] Feedback +-200%
[103] Motor cur. 0-Imax
[104] Torque 0-Tlim
[105] Torque 0-Tnom
[106] Power 0-Pnom
[107] Speed 0-HighLim
[113] Ext. Closed-loop 1 0–100%, (0–20 mA)
[114] Ext. Closed-loop 2 0–100%, (0–20 mA)
[115] Ext. Closed-loop 3 0–100%, (0–20 mA)
[139] Bus ctrl.
[141] Bus ctrl t.o.
26-41 Terminal X42/7 Min. Scale
Range:
0.00 %
*
26-42 Terminal X42/7 Max. Scale
Range:
100.00 %
See principle graph for 6-52 Terminal 42 Output Max Scale.
26-43 Terminal X42/7 Bus Control
Range:
0.00 %
*
26-44 Terminal X42/7 Timeout Preset
Range:
0.00 %
*
®
is a registered Danfoss trademark
Function:
Set the function of terminal X42/7 as
an analog voltage output.
0–100 Hz, (0–20 mA)
Minimum reference - Maximum
reference, (0–20 mA)
-200% to +200% of 20-14 Maximum
Reference/Feedb., (0–20 mA)
0 - Inverter Max. Current (16-37 Inv.
Max. Current), (0–20 mA)
0 - Torque limit (4-16 Torque Limit
Motor Mode), (0–20 mA)
0 - Motor rated torque, (0–20 mA)
0 - Motor rated power, (0–20 mA)
0 - Speed High Limit (4-13 Motor Speed
High Limit [RPM] and 4-14 Motor Speed
High Limit [Hz]), (0–20 mA)
0–100%, (0–20 mA)
0–100%, (0–20 mA)
[0.00 - 200.00 %]
[0.00 - 200.00 %]
*
[0.00 - 100.00 %]
[0.00 - 100.00 %]
Function:
Function: