Parameter Lists
Par.
Parameter description
No. #
21-57
Ext. 3 Reference [Unit]
21-58
Ext. 3 Feedback [Unit]
21-59
Ext. 3 Output [%]
21-6* Ext. CL 3 PID
21-60
Ext. 3 Normal/Inverse Control
21-61
Ext. 3 Proportional Gain
21-62
Ext. 3 Integral Time
21-63
Ext. 3 Differentation Time
21-64
Ext. 3 Dif. Gain Limit
Table 5.20
5.1.20 22-** Application Functions
Par.
Parameter description
No. #
22-0* Miscellaneous
22-00
External Interlock Delay
22-01
Power Filter Time
22-2* No-Flow Detection
22-20
Low Power Auto Set-up
22-21
Low Power Detection
22-22
Low Speed Detection
22-23
No-Flow Function
22-24
No-Flow Delay
22-26
Dry Pump Function
22-27
Dry Pump Delay
22-3* No-Flow Power Tuning
22-30
No-Flow Power
22-31
Power Correction Factor
22-32
Low Speed [RPM]
22-33
Low Speed [Hz]
22-34
Low Speed Power [kW]
22-35
Low Speed Power [HP]
22-36
High Speed [RPM]
22-37
High Speed [Hz]
22-38
High Speed Power [kW]
22-39
High Speed Power [HP]
22-4* Sleep Mode
22-40
Minimum Run Time
22-41
Minimum Sleep Time
22-42
Wake-up Speed [RPM]
22-43
Wake-up Speed [Hz]
22-44
Wake-up Ref./FB Difference
22-45
Setpoint Boost
22-46
Maximum Boost Time
22-5* End of Curve
®
VLT
HVAC Drive Programming Guide
Default value
(SR = Size related)
0.000 ExtPID3Unit
0.000 ExtPID3Unit
0 %
[0] Normal
0.01 N/A
10000.00 s
0.00 s
5.0 N/A
Default value
(SR = Size related)
0 s
0.50 s
[0] OFF
[0] Disabled
[0] Disabled
[0] OFF
10 s
[0] OFF
10 s
0.00 kW
100 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
10 s
10 s
ExpressionLimit
ExpressionLimit
10 %
0 %
60 s
MG11CD22 - VLT
®
is a registered Danfoss trademark
4 set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4 set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
2 set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
-3
Int32
-3
Int32
0
Int32
-
Uint8
-2
Uint16
-2
Uint32
5
5
-2
Uint16
-1
Uint16
Type
0
Uint16
-2
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
-
Uint8
0
Uint16
1
Uint32
0
Uint16
67
Uint16
-1
Uint16
1
Uint32
-2
Uint32
67
Uint16
-1
Uint16
1
Uint32
-2
Uint32
0
Uint16
0
Uint16
67
Uint16
-1
Uint16
0
Int8
0
Int8
0
Uint16
5-23