Danfoss VLT FC 100 Series Programming Manual page 107

Hvac drive
Hide thumbs Also See for VLT FC 100 Series:
Table of Contents

Advertisement

Parameter Description
13-02 Stop Event
Option:
[0]
FALSE
*
3
3
[1]
TRUE
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current
range
[8]
Below I low
[9]
Above I high
[10]
Out of speed
range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb.
range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range See parameter group 5-3* for further
[18]
Reverse
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
3-80
®
VLT
HVAC Drive Programming Guide
Function:
Enters the fixed value of FALSE in the
logic rule.
Enters the fixed value TRUE in the
logic rule.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
MG11CD22 - VLT
13-02 Stop Event
Option:
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
SL Timeout 0
[31]
SL Timeout 1
[32]
SL Timeout 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
[41]
Reset Trip
®
is a registered Danfoss trademark
Function:
Use the result of comparator 0 in the
logic rule.
Use the result of comparator 1 in the
logic rule.
Use the result of comparator 2 in the
logic rule.
Use the result of comparator 3 in the
logic rule.
Use the result of logic rule 0 in the
logic rule.
Use the result of logic rule 1 in the
logic rule.
Use the result of logic rule 2 in the
logic rule.
Use the result of logic rule 3 in the
logic rule.
Use the result of timer 0 in the logic
rule.
Use the result of timer 1 in the logic
rule.
Use the result of timer 2 in the logic
rule.
Use the value of DI18 in the logic rule
(High = TRUE).
Use the value of DI19 in the logic rule
(High = TRUE).
Use the value of DI27 in the logic rule
(High = TRUE).
Use the value of DI29 in the logic rule
(High = TRUE).
Use the value of DI32 in the logic rule
(High = TRUE).
Use the value of DI33 in the logic rule
(High = TRUE).
This event is TRUE if the Adjustable
frequency drive is started by any
means (either via digital input, serial
communication bus or other).
This event is TRUE if the Adjustable
frequency drive is stopped or coasted
by any means (either via digital input,
serial communication bus or other).
This event is TRUE if the Adjustable
frequency drive is tripped (but not

Advertisement

Table of Contents
loading

Table of Contents