How to Program
The Middle section (b) shows up to five variables with
2
2
related unit, regardless of status. In the case of an alarm/
warning, the warning is shown instead of the variables.
The Bottom section (c) always shows the state of the
Adjustable frequency drive in status mode.
It is possible to toggle between three status readout
displays by pressing the [Status] key.
Operating variables with different formatting are shown in
each status screen - see below.
Several values or measurements can be linked to each of
the displayed operating variables. The values /
measurements to be displayed can be defined via
0-20 Display Line 1.1 Small, 0-21 Display Line 1.2 Small,
0-22 Display Line 1.3 Small, 0-23 Display Line 2 Large and
0-24 Display Line 3 Large, which can be accessed via [QUICK
MENU], "Q3 Function Set-ups", "Q3-1 General Settings",
"Q3-13 Display Settings".
Each value/measurement readout parameter selected in
0-20 Display Line 1.1 Small to 0-24 Display Line 3 Large has
its own scale and number of digits after a possible decimal
point. Larger numeric values are displayed with few digits
after the decimal point.
Ex.: Current readout
5.25 A; 15.2 A 105 A.
Status display I
This readout state is standard after startup or initialization.
Use [INFO] to obtain information about the value/
measurement linked to the displayed operating variables
(1.1, 1.2, 1.3, 2, and 3).
See the operating variables shown in the display in this
illustration. 1.1, 1.2 and 1.3 are shown in small size. 2 and
3 are shown in medium size.
1.1
1.2
Figure 2.2
2-2
Status
799 RPM
7.83 A
0.000
53.2%
Auto Remote Ramping
2
3
1.3
MG11CD22 - VLT
®
VLT
HVAC Drive Programming Guide
Status display II
See the operating variables (1.1, 1.2, 1.3, and 2) shown in
the display in this figure.
In the example, Speed, Motor current, Motor power and
Frequency are selected as variables in the first and second
lines.
1.1, 1.2 and 1.3 are shown in small size. 2 is shown in large
size.
Figure 2.3
Status display III
This state displays the event and action of the Smart Logic
Control. For further information, see 3.13 Main Menu -
Smart Logic - Group 13.
Figure 2.4
Display Contrast Adjustment
1 (1)
Press [status] and [
36.4 kW
Press [status] and [
Top section
Middle section
Bottom section
Figure 2.5
®
is a registered Danfoss trademark
Status
207RPM
5.25A
1.1
6.9Hz
Auto Remote Running
Status
778 RPM
0.86 A
State: 0 o 0 (o )
When: -
Do: -
Auto Remote Running
▲
] for darker display
▼
] for brighter display
Status
43 RPM
5.44 A
1.4 Hz
2.9%
! Pwr.card temp (W29)
Auto Remote Running
1 (1)
24.4 kW
1.3
1.2
2
1 (1)
4.0 kW
!
1(1)
25.3 kW