Connect the tube of the Cap Top to the joint part of the
13
Pump.
Then, replace the other Cap Tops in the same way.
You can connect either
tube to the either joint part.
Fix the tubes firmly.
Turn on the Main Power SW, then turn on the Sub Power
14
SW while pressing the Left, Right and Down keys to
enter the Service Mode.
Select [I/S MENU] > [I/S CONTROL] > [CAP] > [OPEN],
15
and press the [ENTER] key. The Capping Unit moves
down.
Move the Head Carriage to lock it by hand to the lock
16
position.
Pump
[ ], [ ], [ ] + SUB POWER ON
MENU
SERVICE MENU
SERVICE MENU
I/S MENU
I/S MENU
I/S CONTROL
I/S CONTROL
CAP
CAP
OPEN