Connect all the cables to the Head Board.
7
Perform the following operations after replacement.
8
1. DIP SW SETTING
2. BATTERY INSTALLATION
3. FIRMWARE INSTALLATION
4. SYSTEM PARAMETER INITIALIZE
5. IP ADDRESS SETTING ( Turn on the power with the Service Mode and set IP Address in the User Menu.)
6. NETWORK CONTROLLER OF FIRMWARE VERSION CONFIRMATION *6
7. SENSOR CHECK
8. CROP MARK SENSOR ADJUSTMENT
9. TIME AND DATE SETTING *7
After performing these operations, perform [Put Parameters] with Peck and write the parameter that was saved
before replacement to the Main Board.
Perform the following operations if it is not possible to transfer the parameters by Peck4.exe.
1. DIP SW SETTING
2. BATTERY INSTALLATION
3. FIRMWARE INSTALLATION
4. SYSTEM PARAMETER INITIALIZE
5. IP ADDRESS SETTING ( Turn on the power with the
Service Mode and set IP Address in the User Menu.)
6. NETWORK CONTROLLER OF
FIRMWARE VERSION CONFIRMATION *6
7. HEAD RANK SETTING
8. SERIAL NUMBER INPUT *1
9. CAP & WIPER CHECK *2
10. CAP HEIGHT CHECK *4
*1 Input the serial number in the [SERVICE MENU] > [SERIAL NO.].
*2 It can be performed in the [SERVICE MENU] > [CAP&WIPER CHECK].
*3 If you can check the value set in the previous Main Board, you can input the value without adjustment.
*4 It can be performed in the [SERVICE MENU] > [CAP ADJUST] > [CHECK GAP].
*5 It can be performed in the [MENU] > [SUB MENU] >[MAINTENANCE] > [DRAIN BOTTLE] > [EMPTY DRAIN
BOTTLE] > [RESET DRAIN COUNTER].
*6 It can be checked in the [4-4 HOW TO UPGRADE FIRMWARE OF THE NETWORK CONTROLLER] Step
Upgrade the Network controller of firmware in reference to [4-4 HOW TO UPGRADE FIRMWARE OF THE
NETWORK CONTROLLER] if the version is not the latest one.
*7 Set the date and time in the [SERVICE MENU] > [SUB MENU] > [CLOCK].
11. SENSOR CHECK
12. LIMIT & CUT DOWN POSITION INITIALIZE
13. LINEAR ENCODER SETUP
14. TOOL PRESSURE ADJUSTMENT *3
15. INK TYPE SETTING
16. HEAD ALIGNMENT
17. CALIBRATION
18. CROP MARK SENSOR ADJUSTMENT
19. CROP-CUT ADJUSTMENT
20. PRINT / CUT POSITION ADJUSTMENT
21. DRAIN BOTTLE COUNTER RESET *5
22. TIME AND DATE SETTING *7
3-44
2.