Roland SOLJET Pro III XC-540 Service Notes page 91

Hide thumbs Also See for SOLJET Pro III XC-540:
Table of Contents

Advertisement

Connect the connector of the Pump Motor.
13
Move the Head Carriage to lock it by hand to the lock
14
position.
After turning on the Main power SW, turn on the Sub
15
Power SW while pressing the Left, Right and Down keys
to enter the Service Mode.
Select [I/S MENU] > [I/S CONTROL] > [CAP] >
16
[CLOSE], and press the [ENTER] key to move up the
Capping Unit 1 step. Align the Guides at the two ends of
the Capping Unit with the Guides at the two ends of the
Head Carriage by moving the Head Carriage by hand.
Then press the [ENTER] key twice more to Cap the
Heads with adjusting the position of the Head Carriage.
Connector
[ ], [ ], [ ] + SUB POWER ON
MENU
SERVICE MENU
Guide
3-29
Pump
[MENU] key
Guide

Hide quick links:

Advertisement

Table of Contents
loading