PERIODIC CL.
SUB MENU
LIGHT
PERIODIC CL.
FAN CHECK
SUB MENU
FAN CHECK
VACUUM FAN
FAN CHECK
BLOWER FAN
TU CHECK
SUB MENU
TU CHECK
TU
TU CHECK
OPTION-TU
SUB MENU
CLOCK
CLOCK
DATE
CLOCK
TIME
This menu is to display and edit the date and time. When it detects the battery exhaustion, [B] is indicated on the time display. In this case,
battery needs to be replaced. However, [B] does not disappear automatically when the battery is replaced. [B] is deleted, when the time is
newly set up with [ENTER] key on the time edit menu.
When the real time clock is not active due to battery exhaustion, the maintenance operation may be performed improperly, such as that it
performs cleaning every time the main power is turned on. The time set here is used for periodic maintenance operations and the time record
of Event Log function. It must be aware that it affects the maintenance operations if the time is changed.
When this setting is changed, it is recorded on Event Log. The time before change is used for the log time, and the new time is recorded as
an information.
DIP SW CHECK
SUB MENU
DIP SW CHECK
bit # [1 2 3 4
SUB MENU
KEY CHECK
NONE
KEY CHECK
SUB MENU
LCD/LED/BUZ CHK
Waiting for incoming data
SUB MENU
DETECTING...
00:
PORT CHECK
Receiving data from network
NETWORK
B3:1073741624B
SUB MENU
MAINTE. MSG.
NONE
MAINTE. MSG.
This menu is to select the type of periodic cleaning which is automatically performed during printing.
Options: WIPE / LIGHT / NORMAL / MEDIUM
LIGHT
WIPE: Wiping and flushing only
LIGHT: Wiping and light evacuation (lighter than regular cleaning) only
NORMAL/MEDIUM: The regular cleanings that can be executed from the control panel
Cleaning period can be set up in PERIODIC CL. menu of the user menu.
This menu is to check FANs.
Select a FAN type with [up] and [down] keys.
Press [ENTER] key for ON/OFF of FANs.
FAN turns off automatically when exit this menu.
TU
START
When Take-Up unit is not connected
TU IS
NOT CONNECTED
OPTION-TU
START
When Take-Up unit is not connected
OPTION-TU IS
NOT CONNECTED
DATE
05/09/10
TIME
01:01:59
TIME
01:01:59
This menu is to check Dip Switch. It displays the real-time status of the No.1 to 8 from the left.
0110 0000
[0] is OFF and [1] is ON.
5 6 7 8]
This menu is to check the operation of panel keys. On this menu, it shows [NONE] on the lower LCD when
any key has not been pressed. It shows the key name when some key is pressed. And it shows a message
of [KEY ERROR] when two keys or more are pressed at the same time, and it is considered that no button
is pressed. You can exit this menu with the [left] key. Therefore, the [left] key needs to be the last button to
be pressed in order to check all keys. As long as the [left] key is pressed at the last, the order of pressing
other keys can be random. When it is left without pressing any key for 10 seconds, or pressing the [left] key,
it exits this menu. At this time, the names of the keys that never been pressed are displayed with a buzzer.
This means that if a buzzer does not go off when exiting, all keys are checked properly. The power cannot
be turned off with the sub power key while performing this menu.
This menu is to check LCD, LED and buzzer. When this menu is selected, it sequentially performs the
Abbreviated
functions of LCD, LED and buzzer. The functions are the followings, ON/OFF of LCD contrast, LCD back
light, ON/OFF of buzzer, display and move of cursor on LCD, and display of all caracters available on LCD.
Returns when completed
Confirm that all functions operate properly, visually and by the sound.
This menu is to confirm the data input from network. The check sum and input data byte are shown on the
0B
lower LCD. On the left, it displays the check sum in hexadecimal of 2 digits. On the right, it displays the
input data byte in decimal of max. 10 digits. They are cleared when [ENTER] key is pressed. The input
data byte overflows at 4GB(4294967296B) and is reset to 0.
This menu is to set up the timing to show the message for maintenance. It displays the message
100 hours
suggesting to perform maintenance when the total print time reaches the specified hours.
Range: NONE, 10 to 999 hours (in 10 hour unit)
4-8
Default: NORMAL
This menu is to confirm that Take-Up unit which is
STOP
connected to the connector equipped for Take-up unit
can be operated properly.
Refer to [4-17 TAKE-UP UNIT OPERATION CHECK].
[TU] menu supports the one named [TAKE UP] of the
two connectors located on the bottom of the right
printer body.
STOP
DATE
05/09/10
Display
TIME
01:01:59
Display
TIME
B
01:01:59
B
Default: NONE
Edit
Edit
It shows [B], when
battery is dead.

Hide quick links:

Advertisement