Roland SOLJET Pro III XC-540 Service Notes page 90

Hide thumbs Also See for SOLJET Pro III XC-540:
Table of Contents

Advertisement

Remove the 2 screws as shown in the figure to remove
9
the Pump Unit.
Remove the 3 screws shown in the figure to remove the
10
Motor from the Pump Unit.
Fix the new Pump Unit to the Motor.
Fix the Pump Unit with the 2 screws as shown in the
11
figure.
Connect the tube (Black) of the Cap Top and the tube
12
(Transparence) of the Drain.
Then, replace the other Pumps in the same way.
Connect the tubes of Cap Top side to the left
joint, and connect the tubes of Drain side to
the right joint.
Fix the tubes firmly.
Make sure that the tubes at the Drain side are
inserted to the Ink trash.
Screw
Motor
Pump Unit
Screw
Tube
(Cap Top side)
Ink trash
3-28
Tube
(Drain side)