Test Pattern is printed.
4
Measure the length of the feed direction and use the value to
calculate the calibration amount with the formula shown
at 5 .
Test Pattern is always printed with offset 0.00%.
Even if a correction is made in the [SETTING]
menu, the Test Pattern is not changed.
Calculate the amount to be calibrated with the formula
5
shown at the right figure.
CA = Calibration Amount
CL = Commanded Length (=400mm)
ML = Measured Length
Select [SETTING] under [CALIB.DEFAULT] menu and enter
6
the calibration value with [
Press [ENTER] key to save the setting.
Parameters can be entered with an increment of
0.01%.
(MAX. +2.00% to MIN. -2.00%)
] and [
] keys.
4-56
500mm
FORMULA
CA = CL - ML
ML
SERVICE MENU
PRINT MENU
[ ]
[ ]
PRINT MENU
CALIB.DEFAULT
[ ]
[ ]
CALIB.DEFAULT
SETTING
[ ]
SETTING
+0.00%
+0.15%
[ ]
Scan
x 100