Select [I/S MENU] > [I/S CONTROL] > [CAP] > [OPEN],
5
and press the [ENTER] key. The Capping Unit moves
down and allows you to move the Head Carriage by hand.
Turn off the Sub Power SW, and then turn off the Main
6
Power SW.
When replacing the Head, it is necessary to
turn off the Main Power SW. If not, the Head of
the Main Board could be broken. We
recommend replacing the Head with plugging
off the AC Cord.
Remove the 4 screws as shown in the figure to remove
7
the Carriage Cover.
There are 2 holes on the Top Cover. 2 upper
side screws can be removed from the Top
Cover.
Remove the Damper Plate, and remove the 2 Ink
8
Dampers from the Head which will be replaced.
Be sure to remove and fix the Ink Damper with
the Head Board Cover fixed. It prevents the ink
from dropping on the Head Board. If the ink
drops on the Head Board, Head will be broken.
SERVICE MENU
I/S MENU
I/S MENU
I/S CONTROL
I/S CONTROL
CAP
CAP
OPEN
Main Power SW
< Rear view >
Carriage Cover
Damper Plate
3-4
[
]
[
]
[
]
[
]