Roland SOLJET Pro III XC-540 Service Notes page 75

Hide thumbs Also See for SOLJET Pro III XC-540:
Table of Contents

Advertisement

Unhook the Cap Frame with holding it by the other hand,
9
and remove it.
Make sure to hold the Cap Frame. There is a
Spring under the Cap Top. The Cap Top will
jump out unless you hold the cap frame when
removing it.
Remove the Cap Top together with the tube.
10
Fix the new Cap Top. Make sure to fix it so that the tube
11
side faces the front.
Note the following contents.
1. Do not to touch the tip of rubber.
2. The Spring is properly fixed under the Cap
Top.
3. Do not to bend the tubes.
Fix the Cap Frame.
12
3-13
Cap Frame
Cap Top
Cap Top
Cap Frame