Roland SOLJET Pro III XC-540 Service Notes page 135

Hide thumbs Also See for SOLJET Pro III XC-540:
Table of Contents

Advertisement

SERVICE MENU
I/S MENU
I/S MENU
I/S CHECK
I/S MENU
PUMP CHECK
I/S MENU
I/S CONTROL
I/S MENU
CAP ADJUST
I/S MENU
CAP AGING
I/S MENU
WIPER AGING
Normal
NOW PROCESSING..
I/S CHECK
Checking
Error
I/S CHECK ERROR
CAP
This menu is for checking the motors and sensors of Cap (Up/Down), Wipers and Slider.
**Make sure to move the head carriage towards left off the capping unit before performing
this check. It may damage Head, Cap or Wiper Unit.
Error Displays
CAP: Error is found on Capping Motor or Capping Sensor.
WIPER: Error is found on Wiper Motor or Wiper Sensor.
PUMP CHECK
NOW PROCESSING..
PUMP SUCTION
PUMP CHECK
NOW PROCESSING..
PUMP RELEASE
This is for checking the pump motor.
The rotation for both ink suction and release can be checked.
All pump motors rotate for 5 seconds and stop.
I/S CONTROL
CAP
CAP
OPEN
I/S CONTROL
WIPER
WIPER
FRONT
CAP: Opens and closes the cap
Cap must not be left opened for long time when ink is installed. Dried ink may damage Head.
Option: OPEN/CLOSE
Default: OPEN
WIPER: Moves the wiper towards front and rear.
Option: FRONT/REAR
Default: FRONT
**Caution: When moving the Head Carriage by hand, pay attention to the Cap height and Wiper position
to avoid clashing. Also, when moving the Cap and Wiper, pay attention to the Carriages,
especially the Head Carriage.
CAP ADJUST
ADJUST POS.
ADJUST POS.
CAP ADJUST
CHECK GAP
CHECK GAP
NOW PROCESSING..
Error (beeps 2 times)
NOW PROCESSING..
4-4
COMPLETED
This is for adjusting and checking
0.00
-2.00
the height of the cap. Refer to
[4-8 CAP HEIGHT ADJUSTMENT].
0.00
CAP AGING
COMPLETED
CAP AGING
FAILED !!
WIPER AGING
COMPLETED
Error (beeps 2 times)
WIPER AGING
FAILED !!
This is to confirm that the
capping is done properly
within the operation range.

Hide quick links:

Advertisement

Table of Contents
loading