Maintenance
Explain following items in reference to the User's Manual.
Disposing of Discharged Ink
[CHECK DRAIN BOTTLE] message appears when a certain amount of discharged fluid collects in the
bottle.
!! IMPORTANT !!
- When you dispose of Discharged Ink, make sure to reset the discharged-fluid count from [MENU] >
[SUB MENU] > [MAINTENANCE] > [DRAIN BOTTLE] and press the [ENTER] key .
Otherwise, "CHECK DRAIN BOTTLE" message appears at the inappropriate timing.
- Never place discarded fluid, in the location with high temperature, or near open flame, chemicals
and explosive material.
- To store discharged fluid temporarily, use the included drain bottle or durable sealed container such
as a metal can or polyethylene tank, and cap tightly.
- Dispose of discharged fluid properly, in accordance with your local laws.
Cleaning function of the Print Heads
(Normal cleaning / Meduim cleaning / Powerful cleaning)
!! IMPORTANT !!
Do not perform the Powerful cleaning more than necessary. It consumes large amount of ink.
Claning the Print Heads using Cleaning Kit
!! IMPORTANT !!
The cleaning is run with the head uncapped.
To prevent the heads from drying out, finish this procedure in 30 minutes or less.
Cleaning other parts
- Platen
- Grit rollers
- Pinch rollers (Raise the Pinch rollers when not in use.)
- Paper sensors (Front and Rear)
- Front cover
- Media clamps
- Bed
!! IMPORTANT !!
Never use gasoline, alcohol, thinner, or any other flammable materials.
Replacing the Wipers
Replacing the Blade
Replacing the Separating Knife
When Not in Use for a Prolonged Period