Remove the 5 screws shown in the figure to remove the
5
Pump Cover together with the Right Inner Plate.
Select [I/S MENU] > [I/S CONTROL] > [CAP] >
6
[CLOSE], and press the [ENTER] key. The Capping Unit
moves up. Press the [ENTER] key 3 times, because the
Capping Unit moves up in 3 steps.
Turn off the Sub Power SW, and then turn off the Main
7
Power SW.
Disconnect the tube (Black) of the Cap Top from the
8
Pump.
Make sure to replace the Cap Top one by one.
If you disconnect the plural tubes at the same
time, there is the risk of wrong connections.