Clear the pump times.
17
Go back to the Service Menu, and select [HISTORY
MENU] > [MOTOR GROUP] > [PUMP TIMES A] >
[CLEAR], and press the [ENTER] key.
Select [SERVICE MENU] > [I/S MENU] > [PUMP
18
CHECK], and perform [PUMP SUCTION] and [PUMP
RELEASE] to check the Pumps work correctly.
Revised 3
Fix the Pump Cover with the 5 screws shown in the
19
figure.
Fix the Front Cover and Right I/S Cover.
20
SERVICE MENU