SYSTEM PARAMETER INITIALIZE
[
] , [
] , [ENTER] + SUB POWER ON
INITIALIZE ALL
SYS,PARAMETER
INITIALIZE
DISPLAYED LANGUAGE
[MENU] + SUB POWER ON
Roland DG Corp.
XC-540
MENU LANGUAGE
JAPANESE
MENU LANGUAGE
ENGLISH
All parameters will be initialized. Turn on the sub power
switch while pressing [
the machine in SYSTEM PARAMETER INITIALIZE mode.
Press [ENTER] key to initialize the SYSTEM PARAMETER
[ ]
or press [POWER] key to cancel when the confirmation
message is displayed at first. The machine turns off
automatically when the initialization is completed. All the
COMPLETED
parameters are reset to the default.
It is necessary to setup the LIMIT POSITION after the
initialization. The error message [SERVICE CALL 0101] is
displayed and the machine never starts before the LIMIT
POSITION is set up.
SERVICE REPORT PRINTING
[
] + SUB POWER ON
SERVICE REPORT
SETUP SHEET
],[
Turn on the sub power switch while
pressing [
machine in the SERVICE REPORT
PRINTING mode.
[SERVICE REPORT] is displayed
and it turns to be the normal mode
after printing.
It starts printing automatically when
ROLL
media is setup. It requires a A4 size
media and prints with Cyan ink.
* Please print the [HISTORY
REPORT] from the service mode.