78
Function Description
Pos : 63.6.8 /Serie 750 (WAGO-I/O-SYST EM)/F unktions beschr eibung/Prozes sabbil d/Infor mation: Weitere Infor mati onen z u Pr oz ess datenbegleitern und Konfigur ationsgrenz en! @ 19\mod_1403788580674_21.doc x @ 156798 @ @ 1
More information on process data qualifiers and configuration limits!
For additional information to the process data qualifiers refer to "Process Data
Qualifiers in Telegrams for PROFINET IO" chapter. For additional information
to the configuration limits refer to "Configuration limits" chapter.
Pos : 63.6.9 /Serie 750 (WAGO-I/O-SYST EM)/F unktions beschr eibung/Prozes sabbil d/Proz ess datenbeglei ter i n PROF INET IO-T elegrammen @ 15\mod_1367500677656_21.doc x @ 118398 @ 3444 @ 1
7.4.2

Process Data Qualifiers in Telegrams for PROFINET IO

7.4.2.1

One Byte IOxS Process Data Qualifiers

In cyclic telegrams, one byte process data qualifiers each are available for
PROFINET IO in the IO controller (IOPS) direction and in the IO device (IOCS)
direction for submodule types carrying the input or output data.
The amount of data in the real-time telegrams is always one byte more than the
respective process data length for these submodule types.
7.4.2.2

Two Byte IOxS Process Data Qualifiers

If the submodule types carry both input and output data, two byte process data
qualifiers each are available in cyclic telegrams for PROFINET IO in the IO
controller (IOxS) direction and in the IO device (IOxS) direction.
The amount of data in the telegram is always two bytes more than the respective
process data length for these submodule types.
7.4.2.3

Examples of One and Two Byte IOxS Process Data Qualifiers

Example 1:
Process data qualifiers for 2-channel digital input modules without
diagnostics and with diagnostics and diagnostic acknowledgement.
Table 32: Example 1 for process data qualifiers for 2-channel digital input modules without
diagnostics and with 1-bit diagnostics and diagnostic acknowledgement.
PNIO submodule
type
2DI (+ 6 BIT I)
2DI (+14 BIT I)
2DI (+30 BIT I)
2DI (- 2 BIT E)
2DI (+ 6 BIT I/O),
DIA, Ackn.
2DI (+14 BIT I/O),
DIA, Ackn.
2DI (+30 BIT I/O),
DIA, Ackn.
2DI (- 2 BIT I/O),
DIA, Ackn.
750-375 PROFINET IO advanced Fieldbus Coupler
IOD  IOC (Provider)
(input data)
7
0
15
8
23
16
31
24
IB0
IOPS
IB0
IB1
IOPS
IB0
IB1
IB2
IB3
IOPS
IB0
IOPS
IOCS
IB0
IB1
IOPS IOCS
IB0
IB1
IB2
IB3
IOPS
WAGO-I/O-SYSTEM 750
Telegram direction
IOC  IOD (Consumer)
39
32 47
40
7
0
15
8
IOCS
IOCS
IOPS
IOCS
IOCS
OB0
IOPS
OB0
OB1
IOPS IOCS OB0
OB1
IOCS
(output data)
23
16
31
24
39
32
47
40
IOCS
IOPS IOCS
OB2
OB3
IOPS
IOCS
Manual