Table 39: Parameterization – Overview of attributes for the station proxy (DAP)
Attributes for the station proxy (DAP)
-

Restart on K-Bus failure

-

Diagnostics of external module/channel errors

-

Internal data bus extension

-
Response to PROFINET IO failure
-
Response to K-Bus failure
-
Activation of the integrated webserver
-
Activation of the WAGO TCP service port
-
Activation of the station-wide PROFIenergy functionality
*)
8.6.1.1
Restart on K-Bus failure
Table 40: Parameterization DAP – Attribute Restart on K-Bus failure
Attribute Name
Restart on K-Bus
failure
8.6.1.2
Diagnostics of external module/channel errors
Table 41: Parameterization DAP – Attribute Diagnostics of external module/channel errors
Attribute Name
Diagnostics of external
module/channel errors
8.6.1.3
Internal data bus extension
Table 42: Parameterization DAP – Attribute Internal data bus extension
Attribute Name
Internal data bus
extension
only for DAP with suffix "PE-DAP"
Attribute Value
POWER ON
RESET
AUTORESET
Attribute Value
0 (false)
1 (true)
Attribute Value
EEPROM-setting is
used
is not used
is used
750-375 PROFINET IO advanced Fieldbus Coupler
Description
After any errors have been corrected can the
internal data bus be returned to operation by
resetting the fieldbus coupler's hardware or
software.
The internal data bus is returned to operation
automatically after any errors have been corrected.
Description
Pending diagnostic messages are not reported to
the respective IO controller irrespective of the
submodule parameterization.
Pending diagnostic messages are reported to the
respective I/O controller depending on the
submodule parameterization.
Description
The settings are made according to the unlock
value saved in the EEPROM.
The internal data bus is operated at the standard
transmission rate.
The internal data bus is operated at the reduced
transmission rate.
WAGO-I/O-SYSTEM 750
*)
Manual
Version 1.1.0