Table 219: Parameterization Ps, Dia - Attribute "Module Diagnosis; Table 220: Parameterization Ps, Dia - Attribute "Sensor Or Load Voltage; Table 221: Parameterization Ps, 750-610, 750-611 - Attribute "Diagnosis: Fuse; Table 222: Parameterization Ps, 750-606 - Attribute "Diagnosis: Undervoltage - WAGO -I/O-SYSTEM 750 Manual

Profinet io advanced fieldbus coupler, 2-port switch, 100 mbit/s, digital, analog and complex signals
Hide thumbs Also See for WAGO-I/O-SYSTEM 750:
Table of Contents

Advertisement

WAGO-I/O-SYSTEM 750
750-375 PROFINET IO advanced Fieldbus Coupler
Table 219: Parameterization PS, DIA – Attribute "Module diagnosis"
Attribute Name
Module diagnosis
Table 220: Parameterization PS, DIA – Attribute "Sensor or load voltage missing"
Attribute Name
Sensor or load voltage
missing
Table 221: Parameterization PS, 750-610, 750-611 – Attribute "Diagnosis: Fuse blown/open"
Attribute Name
Diagnosis: Fuse
blown/open
Table 222: Parameterization PS, 750-606 – Attribute "Diagnosis: Undervoltage"
Attribute Name
Diagnosis:
Undervoltage
Manual
Version 1.1.0
Attribute Value
Description
An error does not lead to transmission of a
diagnostic alarm nor entry in the diagnostics
0 (false)
database of the station proxy.
The respective error leads to an entry in the
diagnostics database of the station proxy if module
diagnostics is enabled. An error leads to
1 (true)
transmission of a diagnostic alarm. The respective
error leads to an entry in the diagnostics database
of the station proxy.
Attribute Value
Description
Absence of the power supply does not lead to
0 (false)
transmission of a diagnostic alarm nor entry in the
diagnostics database of the station proxy.
Absence of the power supply leads to transmission
of a diagnostic alarm. The respective error leads to
1 (true)
an entry in the diagnostics database of the station
proxy if module diagnostics is enabled.
Attribute Value
Description
A defective fuse does not lead to transmission of a
0 (false)
diagnostic alarm nor entry in the diagnostics
database of the station proxy.
A defective fuse leads to transmission of a
diagnostic alarm. The respective error leads to an
1 (true)
entry in the diagnostics database of the station
proxy if module diagnostics is enabled.
Attribute Value
Description
An undervoltage does not lead to transmission of a
0 (false)
diagnostic alarm nor entry in the diagnostics
database of the station proxy.
An undervoltage leads to transmission of a
diagnostic alarm. The respective error leads to an
entry in the diagnostics database of the station
proxy if module diagnostics is enabled. An
1 (true)
undervoltageg leads to transmission of a diagnostic
alarm. The respective error leads to an entry in the
dagnostics database if module diagnostics is
enabled.