WAGO-I/O-SYSTEM 750
750-375 PROFINET IO advanced Fieldbus Coupler
1.6
Abbreviations and Terms
Table 4: Abbreviations and terms used in this manual
Abbreviation/
Term
AIDA
ALCR
API
AR
CAT5
CCx
CPD
CR
DAP
DCP
DIP
GSD
GSDML
HTTP
IOC
IOCR
IOD
Manual
Version 1.1.0
Explanation
Description
Automation
Association of german automotive manufacturers using
Initiative of
generally PROFINET IO in production plants.
German
Automotive
Manufacturers
Alarm CR
Acyclic PROFINET IO real-time channel for transmission of
alarm messages.
Application
Addressing level in addition to the slots and subslots. This
Process Identifier
addressing level allows you to handle different applications
individually to prevent overlap of data storage areas (slots and
subslots) and concurrent access.
Application
Application relationship between IOC or IOS and IOD.
Relationship
Category 5
Cable category 5 according to EIA/TIA-568.
Communication
Communication channels according to TCI-conformance
channels for
classes:
parameterization
CC1:
CC2:
CC3:
Configuration,
Configuration, parameterization and diagnostic (CPD) tools
Parameterization
simplify navigation and communication with fail-safe
and Diagnostic
PROFIsafe I/O modules for setting individual safety-related
parameters.
Communication
Communication relationship between IOC or IOS and IOD.
Relationship
Device Access
Station proxy, network access point, a DAP represents the
Point (DAP)
fieldbus interface and determines the essential properties of
the IO device.
Discovery and
PROFINET protocol used to set station names, IP settings and
basic
other parameters.
Configuration
Protocol
Dual in Line
The DIP switch is comprised of a series of eight individual
Package
shift switches.
General Station
Device description for configuring IO devices within the
Description
engineering system.
General Station
An XML-based language, GSDML is used as the language for
Description
the device description file.
Markup
Language
HyperText
Data exchange protocol used for transmission of internet data,
Transmission
e.g. transfer of websites. Web browsers communicate to web
Protocol
servers via this protocol.
IO Controller
Master in the PROFINET IO network.
Input/Output CR Describes the connection for the PROFINET IO real-time
channel in the input and output direction.
IO Device
Slave in the PROFINET IO network
(here the fieldbus node or station, sometimes also used for the
fieldbus coupler as a station proxy à "DAP").
Notes about this Documentation
Conformance Class 1 via
local configuration interface
Conformance Class 2 via
TCP/IP using Service-Port 6626
Conformance Class 1 via
PROFINET IO supervisor connection
13