Table 130: Parameterization Ai - Attribute "Diagnosis: Measuring Range; Table 131: Parameterization Ai - Attribute "Diagnosis: Measuring Range; Table 132: Parameterization Ai - Attribute "Diagnosis: Line Break; Table 133: Parameterization Ai - Attribute "Diagnosis: Short Circuit - WAGO -I/O-SYSTEM 750 Manual

Profinet io advanced fieldbus coupler, 2-port switch, 100 mbit/s, digital, analog and complex signals
Hide thumbs Also See for WAGO-I/O-SYSTEM 750:
Table of Contents

Advertisement

178
Appendix
Table 130: Parameterization AI – Attribute "Diagnosis: Measuring range overflow"
Attribute Name
Diagnosis: Measuring
range overflow
Table 131: Parameterization AI – Attribute "Diagnosis: Measuring range underflow"
Attribute Name
Diagnosis: Measuring
range underflow
Table 132: Parameterization AI – Attribute "Diagnosis: Line break"
Attribute Name
Diagnosis: Line break
Table 133: Parameterization AI – Attribute "Diagnosis: Short circuit"
Attribute Name
Diagnosis: Short
circuit
750-375 PROFINET IO advanced Fieldbus Coupler
Attribute Value
Description
An overrange on the respective signal channel does
not lead to transmission of a diagnostic alarm nor
0 (false)
entry in the diagnostics database of the station
proxy.
Provided that the channel diagnostics of the
respective signal channel has been activated, an
1 (true)
overrange leads to transmission of a diagnostic
alarm and entry in the diagnostics database of the
station proxy.
Attribute Value
Description
An overrange on the respective signal channel does
not lead to transmission of a diagnostic alarm nor
0 (false)
entry in the diagnostics database of the station
proxy.
Provided that the channel diagnostics of the
respective signal channel has been activated, an
1 (true)
undershoot leads to transmission of a diagnostic
alarm and entry in the diagnostics database of the
station proxy.
Attribute Value
Description
A line break on the respective signal channel does
not lead to transmission of a diagnostic alarm nor
0 (false)
to entry in the diagnostics database of the station
proxy.
Provided that the channel diagnostics of the
respective signal channel has been activated, a line
1 (true)
break leads to transmission of a diagnostic alarm
and entry in the diagnostics database of the station
proxy.
Attribute Value
Description
A short circuit on the respective signal channel
does not lead to transmission of a diagnostic alarm
0 (false)
nor to entry in the diagnostics database of the
station proxy.
Provided that the channel diagnostics of the
respective signal channel has been activated, a
1 (true)
short circuit leads to transmission of a diagnostic
alarm and entry in the diagnostics database of the
station proxy.