For MSDL and DCHIP cards that reside in the same Large System UEM
equipment row, order:
NTND26 MSDL DCH cable in sufficient length to reach from the MSDL
to the I/O Panel of the IPE module that contains the DCHIP
For MSDL and DCHIP cards that reside in different Large System Universal
Equipment Modules (UEM) equipment rows in a multi-row Large System,
order:
NTMF04BA MSDL DCH Extender (50 ft.) cable to reach between the
I/O Panels of the two UEM equipment rows
For SDI/DCH and DCHIP cards that reside in different Small System
cabinets, order:
NTWE04AC Inter-cabinet cable (NTCW84KA to SDI/DCH cable-10 ft)
If IP trunk cards are being installed in IPE modules equipped with
NT8D81BA Backplane to I/O Panel ribbon cable assembly with Molded
Filter Connectors, on a 100BaseTX TLAN subnet connection, order:
NT8D81AA Backplane to I/O Panel ribbon cable assembly compatible
with NTCW84JA Filter Connector Block with ITG-specific filtering for
100BaseTX TLAN subnet connection
Note: Inspect the IPE module to determine if it is equipped with Molded
Filter Connectors on the I/O Panel. Molded Filter Connectors were
shipped in North America during a period from 1998 to 1999. Molded
Filter Connectors can be used with 10BaseT TLAN subnet connections.

Ordering rules for IP Trunk 3.01 (and later) node expansion

To expand an IP Trunk 3.01 (and later) node, the following are required:
For each additional non-DCHIP card:
— one NTVQ92AA IP Trunk 3.01 (and later) Small and Large Systems
32-port expansion package (without DCHIP)
For each additional DCHIP card:
System description