Small System Cable Installation - Nortel 1000 Description, Installation And Operation Manual

Networks communication server, ip trunk installation
Table of Contents

Advertisement

Install and configure IP Trunk 3.01 (and later) node
Procedure 12
Installing the filter and NTND26 cable for MSDL and DCHIP cards in
different Large System equipment rows
1
Install the bracket for the 15-pin I/O panel filter connector in the J16, J17,
J37 or J38 I/O panel opening of the I/O panel of the Network Module or
Core/Net Module that contains the MSDL card.
2
Install the 15-pin I/O panel filter connector on the inward side of the
bracket.
3
Obtain the correct length of the NTND26 DCHI Interface Cable Assembly
to reach from the D-Channel port connector on the faceplate of the MSDL
card to the outward side of the 15-pin filter connector installed in the I/O
panel of the IPE Module that contains the DCHIP card.
The NTND26 DCHI Interface Cable Assembly is available in the following
lengths:
NTND26AA – 6 ft.
NTND26AB – 18 ft.
NTND26AC – 35 ft.
NTND26AD – 50 ft.
4
Connect the appropriate NTND26 cable assembly to the D-Channel port
connector on the faceplate of the MSDL card and to the outward side of
the 15-pin filter connector installed in the I/O panel of the IPE Module that
contains the DCHIP card.
5
Use the NTMF04BA Extension Cable to connect the DCH (P5) connector
of the NTCW84KA to the inward side of the 15-pin I/O panel filter
connector.

Small System cable installation

Follow the steps in Procedure 13 on
installation.
End of Procedure