Appendix G: Upgrade an ITG Trunk 1.0 node to support ISDN signaling trunks

Upgrade the ITG 8-port trunk card ITG basic trunk software

to ITG/ISL trunk software

Step 1 - Remove ITG Trunk 1.0 configuration files

If installing the DCHIP upgrade kit for the NTCW80CA ITG 8-port trunk
card, use the NTCW84LA I/O Panel breakout cable.
Procedure 82
Installing the DCHIP I/O Panel breakout cable from the upgrade kit
1
For the Large System, locate the I/O connector that corresponds to the
leftmost card slot of the ITG 8-port trunk card that is undergoing the
hardware upgrade.
2
Disconnect existing ELAN and serial cables. Remove the existing I/O
panel breakout cable.
3
Install the new cable (NTCW84LA or NTCW84MA). Be sure to use the
screw provided.
4
Reconnect ELAN and serial connectors. For NTCW80CA cards, install a
shielded TLAN cable.
5
Turn to "Install filter and NTND26 cable (for MSDL and DCHIP
cards in same Large System equipment row)" on
DCHIP connector and MSDL cable.
Use the OTM ITG Basic Trunk application to perform this procedure. Once
OTM has been upgraded to 6.6 or later, all the configuration data for the ITG
trunk node will have been converted.
Follow the steps in Procedure 83 on
configuration files from the TABLE, BOOTP and CONFIG directories of
every card in the node to be upgraded.
End of Procedure