Install and configure IP Trunk 3.01 (and later) node
3
Type +++ to bring up the ITG shell CLI prompt:
...+++
When prompted to login, enter the default username and password as:
VxWorks login: itgadmin
Password: itgadmin
ITG>
4
When the ITG shell prompt appears on the TTY, enter the IP address for
the Leader card:
Wait until the display shows "T:21," then enter:
ITG> setLeader "xxx.xxx.xxx.xxx",
"yyy.yyy.yyy.yyy","zzz.zzz.zzz.zzz"
Where:
"xxx.xxx.xxx.xxx" is the Management IP address of Leader 0 on the
ELAN subnet,
"yyy.yyy.yyy.yyy" is the Management Gateway (router) IP address on
the ELAN subnet. If the OTM PC is connected locally to the LAN and
there is no management LAN gateway, then the Gateway IP address
is "0.0.0.0".
"zzz.zzz.zzz.zzz" is the subnet mask for the management IP address
of Leader 0 on the ELAN subnet.
Note 1: All ITG shell commands are case-sensitive. A space separates
the command from the first parameter. The three parameters must each
be enclosed in quotation marks and there must be a comma and no
spaces separating the three parameters.
Note 2: The Management Gateway (router) IP address is used on
reboot to create the IP route table default network route only if
(1) there is no active leader that has this card's management MAC
address in its node properties file and
(2) this card's node properties file is empty (size 0 Kb).
Note 3: IP addresses and subnet masks must be entered in dotted
decimal format.
September 2004