16.
Analog/Digital Converter (ADC)
16.4
Register Descriptions
16.4.11
ADREG1(Conversion Result Register 1)
bit symbol
After reset
bit symbol
After reset
bit symbol
After reset
bit symbol
After reset
Bit
Bit Symbol
31-16
-
15-4
ADR1[11:0]
3-2
-
1
OVR1
0
ADR1RF
2019-02-06
31
30
29
-
-
-
0
0
0
23
22
21
-
-
-
0
0
0
15
14
13
0
0
0
7
6
5
ADR1
0
0
0
Type
R
Read as "0".
R
The value of an AD conversion result
R
Read as "0".
R
OverRun flag
0:No overrun occurred
1:Overrun occurred
This flag is set when a new AD conversion result is stored before the value of ADREG1 is read and is
cleared when the ADREG1 is read.
R
AD conversion result store flag
0:No result stored
1:Result stored
<ADR1RF> is a flag that is set when an AD conversion result is stored in the ADREG1 register and is
cleared when the ADREG1 is read.
28
27
-
-
0
0
20
19
-
-
0
0
12
11
ADR1
0
0
4
3
-
0
0
Function
Page 368
TMPM3V6/M3V4
26
25
24
-
-
-
0
0
0
18
17
16
-
-
-
0
0
0
10
9
8
0
0
0
2
1
0
-
OVR1
ADR1RF
0
0
0