System Settings; Recalibrating Hydraulics - Raven SmarTrax Calibration And Operation Manual

Hide thumbs Also See for SmarTrax:
Table of Contents

Advertisement

SYSTEM SETTINGS

System Setting
Line Acquisition (LA)
Aggressiveness
OnLine (OL) Sensitivity
System Setting
Zero Yaw
Message Frequency - GGA
and VTG
Message Frequency - ZDA
HDOP

RECALIBRATING HYDRAULICS

FIGURE 52. SmarTrax Settings Screen
Selecting Recal Hydraulics restarts the machine's steering calibration process. Refer to Calibrate the Machine's
Steering System section on page 119 for information on completing the machine's steering calibration.
P/N 016-0171-277 Rev. L
ENVIZIO PRO AND CRUIZER II CALIBRATION AND OPERATION
Average
Suggested
Setting
Range
10
4 to 16
10
4 to 20
Average
Acceptable
Setting
Range
0
-2 to 2
10 Hz
10 Hz
.3 Hz
.3 to 10 Hz
2.5
N/A
Function
The LA Aggressiveness value affects how
quickly the machine steers toward a displayed
guidance line when it is traveling further than
24 inches [60 cm] from the desired path.
The OL Sensitivity value affects the response of
the machine while steering within 24 inches [60
cm] of the displayed guidance line.
Function
Indicates amount error in the internal yaw
sensor while no yaw motion is present.
Displays the frequency of GGA messages from
the GPS receiver.
Displays the frequency of GGA messages from
the GPS receiver.
Indicates the quality of the GPS signal.
131

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents