Chapter 3

Disassemble the Planter's Drive System

Note:
The planter's existing drive system is not required for operation once the OmniRow system is
installed. Although it is not required for the entire existing ground drive or hydraulic transmission(s)
to be removed from the planter, it is recommended to do so to help prevent any interference
between the existing planter drive system and the OmniRow system.
Machine's Existing Hex Shaft
FIGURE 2.
7/8" Hex Drive
Shaft
Remove all sections of the 7/8" hex shaft that drives the row units.
1.
Important:
Leave the existing sprocket or gearbox on the left side of the row unit. The OmniRow system
will utilize it and the existing drive chain or flexible shaft to drive the seed meter.
Machine's Supplemental Support Bearings
FIGURE 3.
Remove as
Needed
6
Remove
John Deere Individual Row Control OmniRow Installation Manual
Existing Planter
Drive Chain
Remove