Download And Upload Specification - SATO SG112-ex Operator's Manual

Hide thumbs Also See for SG112-ex:
Table of Contents

Advertisement

8.2 Download and Upload Specification

The following table shows the download and upload specification using the interface and memory card.
Target item
Firmware
Kanji outline font
Kanji font
Configuration (settings)
Font/logo
TTF
Receive buffer
STATUS5 log
All
Firmware
Kanji outline font
Kanji font
User mode information
Font/logo
TTF
Receive buffer
STATUS5 log
All
Note about downloading
• If the file does not exist when selecting the item to be downloaded, that item cannot be selected.
• The font size of "Configuration" and "Font/logo" are different depending on the head density. Do not
download anything between the products with different head density.
• The download file for "Kanji font" varies depending on Chinese/Japanese font.
• For "Configuration", the items listed in the default list will be downloaded (excluding Life Counter, Head
Counter, Cut Counter, MAC Address, BD Address, Main PCB REV, PLD VERSION and PCB Number).
Note about uploading
• When the same file already exists in the save location, the existing file is overwritten.
• An error is raised when the folder to be uploaded cannot be found. Format the card in the Memory mode
before uploading.
• Write protected SD card or USB memory will cause an error when uploading. Release the write protection
from them before uploading.
• Not having enough available memory in SD card or USB memory will cause an error when uploading.
• The date of file creation is according to the calendar if the real-time clock (calendar) kit is installed. If not, the
file creation date will be indicated by the firmware release date.
• For "Configuration", the current contents of the items listed in the default list will be uploaded.
SD card/
USB
Interface
memory
O
O
O
O
O
O
O
O
Files that are uploaded in the upload mode are down-
O
O
loaded.
Files that are uploaded in the upload mode are down-
O
O
loaded.
X
X
X
X
O
X
All the items with "O" above are downloaded.
O
X
O
X
O
X
For NEC font, upload is not available.
When "All" is selected, both binary format and text for-
O
X
mat files are uploaded. (Normally text format file only)
O
X
O
X
X
X
It is possible to upload in the receive data save mode.
O
X
O
X
All the items with "O" above are downloaded.
8 Appendix
Remarks
SG112-ex Operator Manual
193

Hide quick links:

Advertisement

Table of Contents