8.7.5
No Pulse Input in Tear-off Mode (Head Check Disabled)
(1) Operation
Standby
Backfeed to the Print Base position
Print 1st label
Print 2nd label
*1 The time specified by <TW> lapses.
Feed to the
manual cut position
*1 The media is fed to the manual cut position when time (option unit stand-by time; default value -
1000ms) specified by <TW> lapses and no print job is sent.
(Note)
The base position using the Gap sensor is shown above.
(2) Timing chart
Power ON
Label feed
Cut
Head check
Ext.signal
PRIN
PREND(TYPE1)
PREND(TYPE2)
PREND(TYPE3)
PREND(TYPE4)
Backfeed
Operation
Manual Cut
Print head
Print 1st label
Print 2nd label
500ms
Pitch Sensor (Gap)
Feed
Time specified by <TW>.
SG112-ex Operator Manual
8 Appendix