Dc2+De File Download - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

17.13 Common Commands
for All Languages
17.13

DC2+DE File Download

File Download
Command
DC2
HEX code
<12>
16
Default Value
None
When turning off the power switch
Valid range
Valid range and
Printer operation in progress
term of
command
Media sensor information acquisition
in progress
Error
[Function]
This command is used to download the specified file.
[Format]
[DC2]DE,aa,b,c・・・c,d・・・d,e・・・e
[Parameters]
Symbol
Parameter name
Identifier
a
File type
b
File name
c
d
File size
File data
e
[Return data format (normal)]
[ACK]<06>
16
[Return data format (when a command error occurs)]
[NAK]<15>
16
[Return data format (when the same file name error occurs)]
1<31>
16
DE
Parameter
<44>
<45>
,aa,b,c・・・c,d・・・d,e・・・e
16
16
The file is maintained.
The command cannot be received during the printer
operation. ([NAK] return)
The command cannot be received while sensor
information is being acquired. ([NAK] return)
Commands can be received even if an error is occurring.
Valid range
SB: SBPL settings
SZ: SZPL settings
SI: SIPL settings
SD: SDPL settings
ST: STPL settings
CA: Common settings (specified during radio LAN
certification)
0: Font/logo
1: True Type font
2: Wireless LAN certificate (W-iFi Root CA)
3: Wireless LAN certificate (Wi-Fi Private Key)
4: Wireless LAN certificate (Wi-Fi Private Key)
5: Wireless LAN certificate (Wi-Fi EAP_FAST PAC_file)
6: HTTPS certificate
Data within 255 characters including the following
character groups
Alphabet
Numeral
Hyphen ("-")
Underscore ("_")
Period (".")
0 to 999999999 (byte)
368
DC2+DE
Acquisition method
Two characters fixed
acquisition
One character fixed
acquisition
Acquired up to ","
Acquired up to ","
Equivalent to file
size

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents