Limitation On Base Reference Point Adjustment - SATO SG112-ex Operator's Manual

Hide thumbs Also See for SG112-ex:
Table of Contents

Advertisement

5.4.5

Limitation on Base Reference Point Adjustment

After adjusting the print position and stop position, the distance between these two positions should not
exceed one pitch size (including liner) of the media.
Refer to the figure and table below for the adjustment range of the distance between the print position
and the stop position for options.
Adjustment range of the distance between the print position and the stop position for options:
Types of Options
Tear-off mode
Cutter mode
Stop position
for options
point for printing
(Initial)
Initial distance
Adjusted distance
(Min.)
+3.75 mm
-3.75 mm
+3.75 mm
(+0.15")
(-0.15")
(+0.15")
Adjusted distance (Max.)
Adjusted Distance
(Min.)
49.1 mm (1.9")
28.7 mm (1.1")
Base reference
(Initial)
The range of the adjusted distance includes
the base reference point of two media.
-3.75 mm
(-0.15")
Initial Distance
56.6 mm (2.2")
36.2 mm (1.4")
SG112-ex Operator Manual
5 Adjusting the Product
Adjusted Distance
(Max.)
64.1 mm (2.5")
43.7 mm (1.7")
151

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents