Rep 10.6 Thermal Fuse (F1) - Xerox 8850 Service Manual

Hide thumbs Also See for 8850:
Table of Contents

Advertisement

3.
(Figure 6): Reinstall the Web Oiler Assembly on the Printer.
1
Position the Web Oiler Assembly so
that the drive side is on the right side of
the Fuser Drawer
4
Set the Web Oiler back down on
the Fuser Assembly and tighten
down the two mount screws
Figure 6 Reinstalling the Web Oiler Assembly
4.
Return the Printer to normal operating condition.
5.
Enter the Printer diagnostics and perform the following:
a.
10-30 Web Oiler Parameters Reset - to reset the meter if a new Web Oiler is
installed.
b.
10-31 Partial Web Oiler Parameters Reset - to reset the parameters for a partially
used Web. Measure the diameter of the remaining web on the Supply Roll in millime-
ters and enter this value.
Repairs and Adjustments
REP 10.5, REP 10.6
2
Slide the two prongs on the left
side of the Web Oiler Assembly
into the slots on left side of the
Fuser Drawer
3
Lift the right side of the Web Oiler
Assembly slightly and turn the
Takeup Roll clockwise to remove
any remaining slack in that roll

REP 10.6 Thermal Fuse (F1)

Parts List on
PL 10.2
Removal
1.
(Figure 1): Access the Fuser Module.
1
Pull up on the handle and pull open the
Fuser Module Drawer.
Figure 1 Accessing the Fuser Module
2.
Remove the Fuser Heat Roll (REP 10.2).
03/2003
4-126
8850/ 510DP

Hide quick links: