Wear protective gloves when handling parts with silicone oil on them. Do not allow sili-
cone oil to contact your eyes. Silicone oil can cause severe eye irritation. Wash your
hands immediately after handling any component covered with silicone oil.
3.
(Figure 2): Remove the Web Oiler Assembly.
1
Remove the two right side
screws
Figure 2 Removing the Web Oiler Assembly
Repairs and Adjustments
REP 10.3
WARNING
2
Slightly lift the Oil Assembly
and move to the right to
clear the left side tabs
Replacement
1.
(Figure 3): Reinstall the Web Oiler Assembly on the Printer.
1
Position the Web Oiler Assembly so
that the drive side is on the right side of
the Fuser Drawer
4
Set the Web Oiler back down on
the Fuser Assembly and tighten
down the two mount screws
Figure 3 Reinstalling the Web Oiler Assembly
2.
Return the Printer to normal operating condition.
3.
Enter the Printer diagnostics and perform the following:
a.
10-30 Web Oiler Parameters Reset - to reset the meter if a new Web Oiler is
installed.
b.
10-31 Partial Web Oiler Parameters Reset - to reset the parameters for a partially
used Web. Measure the diameter of the remaining web on the Supply Roll in millime-
ters and enter this value.
03/2003
4-120
2
Slide the two prongs on the left
side of the Web Oiler Assembly
into the slots on left side of the
Fuser Drawer
3
Lift the right side of the Web Oiler
Assembly slightly and turn the
Takeup Roll clockwise to remove
any remaining slack in that roll