Clean the Pressure Equalizing Tubes with a vacuum cleaner in order to remove toner
from inside the tubes. Clean the Augers and Magnetic Roll
Ensure that the printer is level.
Check that the mylar Toner Strip PL 9.7, Item 13 for damage.
Run [09-21-4] to distribute the developer material.
Procedure
With the printer in an LL-90 fault condition, enter diagnostic code [9-22] and then press NEXT,
in order to enable the printer to function with an LL-90 fault condition. Enter the code [0361] in
order to exit the diagnostics mode. Re-enter Diagnostics and run 3 test prints [9-55 Pattern 5].
The LL-90 code is displayed as the print is being made.
Y
N
Complete the service call.
Use the last print to check the image density. The image density of the 1.0 Solid Square in
the center of the Test Pattern [0955-5] is equal to or less than the 1.40 Density Square on
the Output Reference SIR 495.1.
Y
N
Perform the Tone-Down Procedure
tone-down, replace the Developer Material
Enter the code [9-21-4] in order to switch on the Main Drive Motor and the Toner Control Ana-
log Signal. Connect the (+) meter lead to the Toner Sensor A22Q1P1-2 and the (-) meter lead
to A22Q1P1-4. There is +15 VDC present.
Y
N
Check for an open or short circuit to ground in the wires connected to A22Q1P 1-2 and
A3P 606-15. If the wires are ok, replace the Main PWB, A3, PL 1.1.
Connect the (+) meter lead to the Main PWB A3606-4 and the (-) meter lead to ground. There
is +5.2 to +6.0 VDC is present.
Y
N
Connect the (+) meter lead to the Toner Sensor A22Q1-1 and the (-) meter lead to
ground. There is greater than +0.2 VDC present.
Y
N
Disconnect Toner Sensor A22Q1P1 from A22Q1J1. Connect the (+) meter lead to
the Main PWB A3J303-16 and the (-) meter lead to ground. There is greater than
+0.2 VDC present.
Y
N
Replace the LVPS, A5, PL 1.1. If the problem persists, replace the Main PWB,
A3,
Check for an open or short circuit to ground in the wires connected to A22Q1-2 and
A22Q1-4. If the wires are OK, replace the Toner Sensor A22Q1, PL 9.9. Run [9-21-
6] Toner Sensor Calibration.
Check for an open or short circuit to ground in the wire connected to A22Q1P1-3. If the
wire is OK, replace the Toner Sensor A22Q1,
tion.
Replace the Main PWB, A3, PL 1.1.
Status Indicator RAPs
LL-90 Overtoned Fault RAP
GP 9 Tone Down
Procedure. If the printer does not
[REP
9.7].
PL
9.9. Run [9-21-6 Toner Sensor Calibra-
03/2003
2-12
8850/ 510DP